Tempat asal: | Cina |
Nama merek: | Brando |
Sertifikasi: | CE |
Nomor model: |
Kuantitas min Order: | 1 pc |
---|---|
Kemasan rincian: | |
Waktu pengiriman: | 7 hari kerja |
Syarat-syarat pembayaran: | L/C, T/T, Western Union |
Menyediakan kemampuan: | 100000pcs per bulan |
Tipe: | Akting Langsung | Bahan tubuh: | Kuningan |
---|---|---|---|
Ukuran Port: | 3/8 '' | Fungsi: | Biasanya tertutup |
Gulungan: | Tidak | Jenis Koneksi Inlet & Outlet: | ODF Solder |
applcation: | Bagian pendingin | CV / KV: | 0.31 /0.27 |
Menyoroti: | katup solenoid normal tertutup,garis solenoid cair |
032F1204 EVR3-038S Danfoss Jenis Solder Koneksi ODF 3/8 '' Solenoid Valve Untuk Pendinginan Tanpa Coil
This type is Danfoss type EVR3 series port size 3/8'' Refrigeration Valve for air conditioning. Tipe ini adalah tipe Danfoss seri port EVR3 ukuran 3/8 '' Katup Pendingin untuk pendingin udara. EVR is a direct or servo-Operated solenoid valve, using for fluid, suction and heat pipe with fluorinated refrigerants. EVR adalah katup solenoida langsung atau servo-Dioperasikan, menggunakan untuk cairan, hisap dan pipa panas dengan pendingin berfluorinasi. EVR is available either as a single valve or the like separate components. EVR tersedia baik sebagai katup tunggal atau komponen terpisah sejenisnya.
Katup Bertindak Langsung:
The direct acting solenoid valve is usually used in small caliber and low pressure environment.it will be able to start in zero pressure, without need of the minimum pressure of the medium. Katup solenoid direct acting biasanya digunakan pada kaliber kecil dan lingkungan bertekanan rendah. Katup solenoida akting langsung ini dapat mulai dalam tekanan nol, tanpa perlu tekanan minimum medium. It is simple to control and has a wide application scope. Mudah dikendalikan dan memiliki cakupan aplikasi yang luas.
Pilot Dioperasikan Valve
The pilot-operated solenoid valve is usually used in big diameter and high pressure occasions.the pilot pressure is required, otherwise it cannot be opened. Katup solenoida yang dioperasikan pilot biasanya digunakan dalam situasi berdiameter besar dan tekanan tinggi. Tekanan pilot diperlukan, jika tidak, katup tidak dapat dibuka. In addition, the flow capability of the pilot-operated solenoid valve is bigger than that of the direct acting solenoid valve. Selain itu, kemampuan aliran dari katup solenoida yang dioperasikan pilot lebih besar dari pada katup solenoida yang bekerja langsung.
Dimensi:
Lembar Data Seri EVR:
Tipe
|
Ukuran koneksi (inci)
|
Ukuran koneksi
(mm)
|
Max. Maks. working Pressure Tekanan Pekerjaan
(batang)
|
Nilai kv
(m3 / jam)
|
Kode no.
|
EVR 2
|
1/4
|
-
|
45.2
|
0,15
|
032F1201
|
-
|
6
|
45.2
|
0,15
|
032F1202
|
|
EVR 3
|
1/4
|
-
|
45.2
|
0,26
|
032F1206
|
3/8
|
-
|
45.2
|
0,26
|
032F1204
|
|
-
|
6
|
45.2
|
0,26
|
032F1207
|
|
-
|
10
|
45.2
|
0,26
|
032F1208
|
|
EVR 6
|
1/2
|
-
|
45.2
|
0,80
|
032L1209
|
3/8
|
-
|
45.2
|
0,80
|
032L1212
|
|
-
|
10
|
45.2
|
0,80
|
032L1213
|
|
-
|
12
|
45.2
|
0,80
|
032L1236
|
|
EVR 10
|
1/2
|
-
|
35
|
1.9
|
032L1217
|
-
|
12
|
35
|
1.9
|
032L1218
|
|
5/8
|
16
|
35
|
1.9
|
032L1214
|
|
EVR 15
|
7/8
|
22
|
32
|
2.6
|
032L1225
|
5/8
|
16
|
32
|
2.6
|
032L1228
|
|
EVR 20
|
7/8
|
22
|
32
|
5.0
|
032L1240
|
1 1/8
|
-
|
32
|
5.0
|
032L1244
|
|
-
|
28
|
32
|
5.0
|
032L1245
|
|
7/8
|
22
|
32
|
5.0
|
032L1264
|
|
EVR 22
|
1 3/8
|
35
|
32
|
6.0
|
032L3267
|
EVR 25
|
1 1/8
|
-
|
32
|
10.0
|
032L2201
|
-
|
28
|
32
|
10.0
|
032L2206
|
|
1 3/8
|
-
|
32
|
10.0
|
032L2207
|
|
1 3/8
|
-
|
32
|
10.0
|
032L2208
|
|
EVR 32
|
1 5/8
|
-
|
32
|
10.0
|
042L1104
|
-
|
35
|
32
|
16.0
|
042L1105
|
|
-
|
35
|
32
|
16.0
|
042L1106
|
|
-
|
42
|
32
|
32
|
042L1108
|
|
EVR 40
|
1 5/8
|
-
|
32
|
32
|
042L1110
|
2 1/8
|
-
|
32
|
32
|
042L1112
|
|
|
42
|
32
|
32
|
042L1114
|
Fitur:
Lengkap berbagai katup solenoid untuk pendingin, pembekuan dan pabrik pendingin udara
Disediakan dalam versi yang biasanya ditutup (NC) dan biasanya terbuka (NO) dengan koil yang tidak berenergi
Berbagai pilihan kumparan untuk ac dan dc
Cocok untuk semua refrigeran berfluorinasi, termasuk refrigeran yang mudah terbakar
Dirancang untuk suhu media hingga 105 ° C
MOPD hingga 25 bar dengan kumparan 12 W
Koneksi flare hingga 5/8 in.
Koneksi solder hingga 2 1/8 in.
Extended ends on solder versions make the installation easy. Perpanjangan ujung pada versi solder memudahkan pemasangan. It is not necessary to dismantle the valve when soldering in. Tidak perlu membongkar katup saat menyolder.
Tersedia dalam versi konveksi flare, solder dan flange
Fokus pada tuntutan Anda, Tawarkan solusi terbaik kepada Anda:
√ Hubungi kami jika ada beberapa poin yang Anda ragukan
√ Hubungi kami jika suatu tempat perlu diubah
√ Hubungi kami jika bukan yang Anda cari
√ Hubungi kami jika Anda sedang mendesain
Selamat datang di pertanyaan dan pertanyaan Anda!
Kontak Person: Brandon Bao
Tel: 86-13454729544
Faks: 86-574-83879820
3 ''DMF-Z-76S BFEC Diafragma Pulse Jet Solenoid Valve Untuk Filter Bag
CA25DD Goyen Type DD Series Pulse Jet Diaphragm Valve Untuk Kolektor Debu
1 ''SCG353A044 ASCO Type Diafragma Pulse Jet Valve Untuk Menghilangkan Debu
EVR 3 NC 032F8107 1/4 '' Danfoss Jenis Refrigeration Solenoid Valve 220VAC
1028/3 Castel Tipe 3/8 ''Katup Solenoid Pendingin HM2 220VAC 230VAC
EVRA 40 EN-JS1025 Danfoss Jenis Amonia Solenoid Valve 042H1128 042H1132
C113443 C113444 Diafragma Untuk ASCO Pulse Valve SCG353A043 SCG353A044
Diafragma Untuk BFEC Pulse Valve 1.5 ''DMF-Z-40S DMF-ZM-40S DMF-Y-40S
Kit Diafragma K7600 K7601 Untuk Katup Solenoid Pulsa Goyen CA76T CA76MM